WFI Water Hammer Dampener

Water hammer dampener for WFI systems

Features

  • Installed inline as close to pump discharge as possible
  • No need for a seperate gasket
  • Adjustable air pressure to optimize the dampener for the local process

Specifications

Brand

ROMYNOX

Description

The WFI Water Hammer Dampener is the high purity altarnative for water hammer, designed for aseptic processes requiring clean-in-place components.
Description

The WFI Water Hammer Dampener is designed for clean-in-place aseptic processes and very suitable for WFI systems. The dampener can be installed very close to the pump to absorb the pulse as much as possible as its source. It needs to be installed vertical.

UNIQUE SLEEVE

The Water Hammer Dampener has got a unique inline flow-through sleeve which is designed to create a steady flow with zero dead leg. The sleeve expands at a high pressure and returns to it’s original form afterwards. The sleeve ends connect directly with a tri-clamp without the need for a seperate gasket.

Kindly notice that those products are engineered and produced following client requests. Each product needs to be calibrated for special properties such as size or connection. In order to make it possible, our sales team will assist you to determine those criteria together. Only when this process is finished ROMYNOX will we be able to produce a quote and share a price.

If you need to get in touch with our engineers, please visit our “Contact Us” page and fill out the form.

Our team will respond to your inquiry as soon as possible.

Technical information

SizesSee picture
Connection2 1/2″ tri-clamp connection
Max pressure10,3 bar (150 psi)
MaterialBody: 1.4435 (316L)
SealsMembranes (silicone, EPDM)
CertificatesUSP Class VI